Because of a lapse in government funding, the information on this website may not be up to date, transactions submitted via the website may not be processed, and the agency may not be able to respond to inquiries until appropriations are enacted.
The NIH Clinical Center (the research hospital of NIH) is open. For more details about its operating status, please visit https://cc.nih.gov.
Updates regarding government operating status and resumption of normal operations can be found at https://opm.gov.

Ante la falta de fondos del gobierno federal, no se actualizará este sitio web y la organización no responderá a transacciones ni consultas hasta que se aprueben los fondos.
 El Centro Clínico de los Institutos Nacionales de la Salud  (el hospital de investigación) permanecerá abierto. Consulte https://cc.nih.gov(en inglés)
Infórmese sobre el funcionamiento del gobierno federal y el reinicio de las actividades en https://opm.gov.

Year of Publication: 2007
Project: BOLD Connectivity Dynamics
FIM Authors:
Authors:
  • Fuhrmann Alpert
  • F. Sun
  • D. Handwerker
  • M. D'Esposito
  • R. Knight
Abstract:

This work addresses the choice of imaging flip angle in blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI). When noise of physiological origin becomes the dominant noise source in fMRI timeseries, it causes a nonlinear dependence of the temporal signal-to-noise ratio (TSNR) versus signal-to-noise ratio (SNR) that can be exploited to perform BOLD fMRI at angles well below the Ernst angle without any detrimental effect on our ability to detect sites of neuronal activation. We show, both experimentally and theoretically, that for situations where available SNR is high and physiological noise dominates over system/thermal noise, although TSNR still reaches it maximum for the Ernst angle, reduction of imaging flip angle well below this angle results in negligible loss in TSNR. Moreover, we provide a way to compute a suggested imaging flip angle, which constitutes a conservative estimate of the minimum flip angle that can be used under given experimental SNR and physiological noise levels. For our experimental conditions, this suggested angle equals 7.63 degrees for the grey matter compartment, while the Ernst angle=77 degrees. Finally, using data from eight subjects with a combined visual-motor task we show that imaging at angles as low as 9 degrees introduces no significant differences in observed hemodynamic response time-course, contrast-to-noise ratio, voxel-wise effect size or statistical maps of activation as compared to imaging at 75 degrees (an angle close to the Ernst angle). These results suggest that using low flip angles in BOLD fMRI experimentation to obtain benefits such as (1) reduction of RF power, (2) limitation of apparent T(1)-related inflow effects, (3) reduction of through-plane motion artifacts, (4) lower levels of physiological noise, and (5) improved tissue contrast is feasible when physiological noise dominates and SNR is high.


Journal: NeuroImage
Volume: 34
URL:
DOI: 10.1016/j.neuroimage.2006.10.020