Because of a lapse in government funding, the information on this website may not be up to date, transactions submitted via the website may not be processed, and the agency may not be able to respond to inquiries until appropriations are enacted.
The NIH Clinical Center (the research hospital of NIH) is open. For more details about its operating status, please visit https://cc.nih.gov.
Updates regarding government operating status and resumption of normal operations can be found at https://opm.gov.

Ante la falta de fondos del gobierno federal, no se actualizará este sitio web y la organización no responderá a transacciones ni consultas hasta que se aprueben los fondos.
 El Centro Clínico de los Institutos Nacionales de la Salud  (el hospital de investigación) permanecerá abierto. Consulte https://cc.nih.gov(en inglés)
Infórmese sobre el funcionamiento del gobierno federal y el reinicio de las actividades en https://opm.gov.

Year of Publication: 2010
Project: BOLD Connectivity Dynamics
FIM Authors:
Authors:
  • S. Hu
  • O. Olulade
  • J. Gonzalez-Castillo
  • J. Santos
  • S. Kim
  • G. Tamer
  • W. Luh
  • T. TM
Abstract:

A confound for functional magnetic resonance imaging (fMRI), especially for auditory studies, is the presence of imaging acoustic noise generated mainly as a byproduct of rapid gradient switching during volume acquisition and, to a lesser extent, the radiofrequency transmit. This work utilized a novel pulse sequence to present actual imaging acoustic noise for characterization of the induced hemodynamic responses and assessment of linearity in the primary auditory cortex with respect to noise duration. Results show that responses to brief duration (46 ms) imaging acoustic noise is highly nonlinear while responses to longer duration (>1 s) imaging acoustic noise becomes approximately linear, with the right primary auditory cortex exhibiting a higher degree of nonlinearity than the left for the investigated noise durations. This study also assessed the spatial extent of activation induced by imaging acoustic noise, showing that the use of modeled responses (specific to imaging acoustic noise) as the reference waveform revealed additional activations in the auditory cortex not observed with a canonical gamma variate reference waveform, suggesting an improvement in detection sensitivity for imaging acoustic noise-induced activity. Longer duration (1.5 s) imaging acoustic noise was observed to induce activity that expanded outwards from Heschl's gyrus to cover the superior temporal gyrus as well as parts of the middle temporal gyrus and insula, potentially affecting higher level acoustic processing.


Journal: Neuroimage
Volume: 49
URL:
DOI: